Troubleshooting
Table10-3Flowproblemsandrecommendedactions
continued
ProblemPossiblecausesRecommendedactions
Erraticnon-zeroow
ratewhenowis
steady
Slugow
Dampingvaluetoolow
Pluggedowtube
Excessiveorerraticdrivegain
Outputwiringproblem
Problemwithreceivingdevice
Wiringproblem
Verifythatthesensororientationis
appropriateforyourapplication(referto
thesensorinstallationmanual).
Checkthedrivegainandthepickoff
voltage.SeeSection10.25andSection
10.26.
Forinstallationwith9-wirecabling,
verifythatthe9-wirecableiscorrectly
grounded.
Checkthewiringbetweenthesensorand
transmitter.SeeSection10.10.
Forsensorswithajunctionbox,check
formoistureinthejunctionbox.
Purgetheowtubes.
Checkforopenorleakingvalvesor
seals.
Checkforsourcesofvibration.
Verifydampingconguration.
Verifythatthemeasurementunitsare
conguredcorrectlyforyourapplication.
Checkforslugow.SeeSection10.24.
Checkforradiofrequencyinterference.
SeeSection10.12.
ContactMicroMotion.
Inaccurateowrate
orbatchtotal
Badowcalibrationfactor
Inappropriatemeasurementunit
Badsensorzero
Baddensitycalibrationfactors
Badowmetergrounding
Slugow
Problemwithreceivingdevice
Wiringproblem
Verifycharacterizationparameters.
Verifythatthemeasurementunitsare
conguredcorrectlyforyourapplication.
Zerothemeter.
Checkgrounding.SeeSection10.11.
Checkforslugow.SeeSection10.24.
Verifythatthereceivingdevice,andthe
wiringbetweenthetransmitterandthe
receivingdevice
Checkthewiringbetweenthesensorand
transmitter.SeeSection10.10.