Release date: 01 Nov 2021
Revision: 1.0
4.5.6 Battery limitations
Table 11 Battery limitations
Maximum battery voltage 25.2 V
Minimum average battery voltage 21.0 V
Failsafe 1 autonomous return to home
voltage
21.0 V
Failsafe 2 autonomous land voltage 20 V
4.5.7 Range limitations
4.5.7.1 Command and control link
Table 12 Command and control link limitations
Maximum altitude range 1 km
Maximum operating range 1 km visual line of sight/extended visual line of sight
Maximum flight endurance 40 minutes
visual line of sight by EASA standards 500 m