Proline t-mass I 300 HART Commissioning
Endress+Hauser 119
9.6 Configuration management
After commissioning, you can save the current device configurationor restore the previous
device configuration.
You can do so using the Configuration management parameter and the related options
found in the Configuration backup submenu.
Navigation
"Setup" menu → Advanced setup → Configuration backup
Configuration backup
Operating time
→  110
Last backup
→  110
Configuration management
→  110
Backup state
→  111
Comparison result
→  111
Parameter overview with brief description
Parameter Description User interface / Selection
Operating time Indicates how long the device has been in operation. Days (d), hours (h), minutes (m) and seconds
(s)
Last backup Shows when the last data backup was saved to HistoROM
backup.
Days (d), hours (h), minutes (m) and seconds
(s)
Configuration management Select action for managing the device data in the HistoROM
backup.
Cancel
Execute backup
Restore
Compare
Clear backup data
Backup state Shows the current status of data saving or restoring. None
Backup in progress
Restoring in progress
Delete in progress
Compare in progress
Restoring failed
Backup failed
Comparison result Comparison of current device data with HistoROM backup. Settings identical
Settings not identical
No backup available
Backup settings corrupt
Check not done