Proline t-mass I 300 HART Technical data
Endress+Hauser 165
DN
[mm]
Full scale value [kg/h]
(Air, 20°C, 1.013 bar a)
Full scale value [Nm3/h]
(Air, 0°C, 1.013 bar a)
Minimum Maximum Minimum Maximum
300 293 29 340 227 22 689
400 522 52 160 403 40 337
500 815 81 500 630 63 026
600 1 174 117 360 908 90 758
700 1 597 159 740 1 235 123 531
1 000 3 260 326 000 2 521 252 105
1 500 7 335 733 501 5 672 567 236
• Order code for "Sensor version; sensor; insertion tube:", option SB "Bidirectional; stainless
steel; stainless steel"
• Order code for "Sensor version; sensor; insertion tube:", option SC "Reverse flow detection;
stainless steel; stainless steel"
DN
[mm]
Full scale value [kg/h]
(Air, 20°C, 1.013 bar a)
Full scale value [Nm3/h]
(Air, 0°C, 1.013 bar a)
Minimum Maximum Minimum Maximum
80 13 1 310 10 1 012
100 23 2 310 17 1 786
150 47 4 750 36 3 673
200 84 8 475 65 6 553
250 132 13 250 102 10 246
300 190 19 000 146 14 692
400 337 33 750 260 26 099
500 530 53 000 409 40 986
600 762 76 250 589 58 966
700 1 038 103 820 802 80 286
1 000 2 119 211 900 1 638 163 868
1 500 4 767 476 750 3 686 368 683
US units
• Order code for "Sensor version; sensor; insertion tube", option SA "Unidirectional;
stainless steel; stainless steel"
• Order code for "Sensor version; sensor; insertion tube", option HA "Unidirectional; Alloy;
stainless steel"
DN
[in]
Full scale value [lb/h]
(Air, 68°F, 14.7 psi a)
Full scale value [SCFM]
(Air, 59°F, 14.7 psi a)
Minimum Maximum Minimum Maximum
3 42 4 173 9 909
4 74 7 419 16 1 616
6 167 16 693 36 3 636
8 297 29 677 65 6 464
10 464 46 371 101 10 100
12 668 66 774 145 14 544