3 Block MEASURED VARIABLES Device Functions Proline Promass 83 MODBUS RS485
16 Endress+Hauser
UNIT VOLUME
FLOW
MODBUS register:
Data type:
Access:
0402
2103
Integer
read/write
For selecting the unit for displaying the volume flow (volume/time).
The unit you select here is also valid for:
Current output
Frequency output
Relay switch points (limit value for volume flow, flow direction)
Low flow cut off
Options:
Metric:
0 to 3 = cubic centimeter cm
3
/s; cm
3
/min; cm
3
/h; cm
3
/day
4 to 7 = cubic decimeter dm
3
/s; dm
3
/min; dm
3
/h; dm
3
/day
8 to 11 = cubic meter m
3
/s; m
3
/min; m
3
/h; m
3
/day
12 to 15 = milliliter ml/s; ml/min; ml/h; ml/day
16 to 19 = liter l/s; l/min; l/h; l/day
20 to 23 = hectoliter hl/s; hl/min; hl/h; hl/day
24 to 27 = megaliter Ml/s; Ml/min; Ml/h; Ml/day
US:
28 to 31 = cubic centimeter cc/s; cc/min; cc/h; cc/day
32 to 35 = acre foot af/s; af/min; af/h; af/day
36 to 39 = cubic foot ft
3
/s; ft
3
/min; ft
3
/h; ft
3
/day
40 to 43 = fluid ounce oz f/s; oz f/min; oz f/h; oz f/day
44 to 47 = gallon gal/s; gal/min; gal/h; gal/day
88 to 92 = kilo gallon Kgal/s; Kgal/min; Kgal/h; Kgal/day
48 to 51 = million gallon Mgal/s; Mgal/min; Mgal/h; Mgal/day
52 to 55 = barrel (normal fluids: 31.5 gal/bbl) bbl/s; bbl/min; bbl/h; bbl/day
56 to 59 = barrel (beer: 31.0 gal/bbl) bbl/s; bbl/min; bbl/h; bbl/day
60 to 63 = barrel (petrochemicals: 42.0 gal/bbl) bbl/s; bbl/min; bbl/h;
bbl/day
64 to 67 = barrel (filling tanks: 55.0 gal/bbl) bbl/s; bbl/min; bbl/h; bbl/day
Imperial:
68 to 71 = gallon gal/s; gal/min; gal/h; gal/day
72 to 75 = mega gallon Mgal/s; Mgal/min; Mgal/h; Mgal/day
76 to 79 = barrel (beer: 36.0 gal/bbl) bbl/s; bbl/min; bbl/h; bbl/day
80 to 83 = barrel (petrochemicals: 34.97 gal/bbl) bbl/s; bbl/min; bbl/h;
bbl/day
Factory setting: Country-dependent (m
3
/h or US-Mgal/day)
UNIT VOLUME
MODBUS register:
Data type:
Access:
0403
2104
Integer
read/write
For selecting the unit for displaying the volume.
The unit you select here is also valid for: Pulse weighting (e.g. m
3
/p)
Options:
0 to 6 = metric cm
3
; dm
3
; m
3
; ml; l; hl; Ml Mega
7 to 16 = US cc; af; ft
3
; oz f; gal; Mgal; bbl (normal fluids); bbl (beer);
bbl (petrochemicals); bbl (filling tanks);
22 = Kgal
17 to 20 = Imperial gal; Mgal; bbl (beer); bbl (petrochemicals)
Factory setting: m
3
! Note!
The unit of the totalizers is independent of your choice here. The unit for each
totalizer is selected separately for the totalizer in question.
Function description
MEASURED VARIABLES SYSTEM UNITS CONFIGURATION