5 Block USER INTERFACE Device Functions Proline Promass 83 MODBUS RS485
46 Endress+Hauser
FORMAT
MODBUS register:
Data type:
Access:
2422
2533
Integer
read/write
For selecting the maximum number of places after the decimal point to be
displayed for the display value.
Options:
0 = XXXXX
1 = XXXX.X
2 = XXX.XX
3 = XX.XXX
4 = X.XXXX
Factory setting:
X.XXXX
! Note!
• Note that this setting only affects the reading as it appears on the display, it has
no influence on the accuracy of the system's calculations.
• The places after the decimal point as computed by the measuring device cannot
always be displayed, depending on this setting and the engineering unit. In
such instances an arrow appears on the display between the measuring value
and the engineering unit (e.g. 1.2 → kg/h), indicating that the measuring
system is computing with more decimal places than can be shown on the
display.
DISPLAY MODE
MODBUS register:
Data type:
Access:
2423
2536
Integer
read/write
! Note!
Function is not available unless one of the following was selected in the ASSIGN
function (2420):
• MASS FLOW BARGRAPH IN %
• VOLUME FLOW BARGRAPH IN %
• CORRECTED VOLUME FLOW BARGRAPH IN %
Use this function to define the format of the bar graph.
Options:
0 = STANDARD
1 = SYMMETRY
Factory setting: STANDARD
Illustration of bar graph
A0001258
Fig. 7 : Bar graph for STANDARD option
Simple bar graph with 25 / 50 / 75% gradations and integrated sign.
A0001259
Fig. 8: Bar graph for SYMMETRY option Symmetrical bar graph for positive and
negative directions of flow, with −50 / 0 / +50% gradations and
integrated sign.
Function description
USER INTERFACE → ADDITIONAL LINE → MULTIPLEX