RECLOSER CONTROL EVRC2A-N6,NT
USER’S MANUAL
ENTEC
ELECTRIC & ELECTRONIC CO., LTD
ENTEC
Copyright © 2002 by ENTEC ELECTRIC & ELECTRONIC CO., LTD all right reserved. Forerunner Distribution & Automation
Release Date: Feb. 2013 / Manual Revision: 7.13

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Entec EVRC2A-N6-NT and is the answer not in the manual?

Summary

1. INTRODUCTION

1.1. Description

Describes the EVRC2A's role in protective coordination and fault clearance for distribution systems.

1.2. Summary of Features

Provides an overview of the recloser's protection, metering, and monitoring capabilities.

2. TECHNICAL SPECIFICATIONS

2.1. Inputs and Outputs

Details the system specifications, frequency, control voltage, and DC power output.

2.2. Type Withstand Tests

Outlines dielectric strength, impulse voltage, surge withstand, and vibration test standards.

2.3. Metering Accuracy

Presents metering accuracy specifications for current, voltage, power factor, and other parameters.

2.4. Protection Elements

Details various protection elements like overcurrent, undervoltage, and overfrequency.

2.5. Monitoring

Describes monitoring functions including demand, synchronism check, trip counters, and recloser wear.

2.6. Recorder

Explains waveform capture, system event recorder, and load profile recording capabilities.

2.7. Communications

Details communication port settings for RS232, RS485, and Ethernet interfaces.

3. USER INTERFACE PANEL

3.1. Construction

Describes the panel's construction, consisting of operation, local control, and indication sections.

3.1.2. Local Control Section

Explains the indicators and functions within the local control section of the panel.

3.2. LCD Display

Details the LCD display specifications and menu structure.

3.3. Using the LCD Menu

Provides guidance on navigating and operating the EVRC2A using the LCD menu.

4. SELECT SETBANK

SELECT SETBANK; PRIMARY

Allows selection and setting of the primary configuration bank for the system.

SELECT SETBANK; ALTERNATE

Allows selection and setting of the alternate configuration bank for the system.

SELECT SETBANK; EDIT

Enables editing of a selected configuration bank for system settings.

5. RELAY SETUP

5.1. Passcode

Procedure for changing the device passcode for security access.

5.2. Communication

Overview of communication ports and settings for the EVRC2A.

5.2.2. Protocol Setup

Configuration details for various communication protocols like DNP3.0, IEC60870-5-101/104, and MODBUS.

5.3. Clock

Procedure for configuring the current date and time settings.

5.8. Time Set & Display Type - Option

Settings for date display format and GMT/Local time synchronization.

6. SYSTEM SETUP

6.1. Current Sensing

Setup for phase, ground, and SEF CT primary current values.

6.2. Line VS Sensing

Configuration for measuring source voltage including connect type and VT ratio.

6.3. Line VL Sensing

Configuration for measuring load voltage including connect type and VT ratio.

6.4. System Power

Settings for line frequency, phase rotation, and install direction.

6.8. Loop Control - Option

Configuration for loop control functionality using sectionalizing, midpoint, and tie reclosers.

6.10. Power Quality - Option

Enables and configures power quality monitoring for outage, sag, swell, and unbalance events.

7. PROTECTION

7.1. Reclose (79)

Configuration of reclosing operations, including lockout counts and time intervals.

7.2. Phase (Fast;Delay) Time Overcurrents (51 P)

Setup for phase overcurrent protection with various time curves and pickup settings.

7.3. Ground (Fast;Delay) Time Overcurrent (51 G)

Setup for ground overcurrent protection with various time curves and pickup settings.

7.4. Sensitive Earth Fault (SEF)

Configuration for sensitive earth fault protection, including pickup and time delay.

7.12. Cold Load Pickup

Function to prevent incorrect operation due to inrush current upon load restoration.

7.13. Directional Controls (67)

Configuration for directional protection based on current flow direction and torque angle.

7.18. Time Overcurrent Curves

Details standard and user-defined time overcurrent curve characteristics.

8. MONITORING

8.1. Demand

Monitoring of phase, ground, and negative sequence current demand values.

8.3. Trip Counter

Records and displays trip, fault, and system restart counts.

8.4. Recloser Wear

Monitors the contact life of the recloser based on fault current interruptions.

8.6. Fault Locator

Calculates fault distance based on voltage and current variations and impedance estimation.

9. STATUS

9.1. OPTO Inputs

Displays the status of external input ports (OPEN/CLOSE).

9.2. Relay Outputs

Displays the status of external output ports (OPEN/CLOSE).

9.3. Clock

Shows the current system time, differentiating between local and GMT.

10. METERING

10.1. Metering Elements

Lists the values contained in the metering elements of the EVRC2A.

10.1.1. Current

Details measured RMS currents and phasors for phase, ground, and sequences.

10.1.2. Voltage(Souce Side, Load Side)

Details measured RMS voltages and phasors for source and load sides.

10.1.7. Demand

Displays actual and maximum demand values for current, power, and energy.

10.2. Accuracy

Presents metering accuracy specifications for various parameters.

11. MAINTENANCE

11.1. Counters

Records and displays system operation counters like trip, fault, and restart counts.

11.3. Output Relay Test

Procedure for testing the relay output ports (1-8) for proper functionality.

12. EVENT RECORDER

12.1. Waveform Capture

Records fault cycle waveforms with detailed data and displays summary on LCD.

12.2. System Event Recorder

Records system status changes, storing up to 2048 events.

12.3. Load Profile

Records demand values over set time intervals for load profile analysis.

12.5. Fault Trip Event Recorder - Option

Records fault trip occurrences, time, and phase fault currents.

12.6. Power Quality Event Recorder - Option

Monitors and records outage, sag/swell, and unbalance events for analysis.

13. INSTALLATION

13.1. User Interface Door and Power Switch

Describes the user interface door, control power switches, and AC power outlet.

13.3. Dimensions and Mounting Plan

Provides physical dimensions and mounting details for the EVRC2A unit.

13.4. Earth Wiring Diagram

Illustrates the proper grounding connections for the control cubicle.

13.9. EVRC2 A Wiring Diagram - VD Type

Detailed wiring diagram for the EVRC2A using VD type voltage inputs.

13.10. EVRC2 A Wiring Diagram - VT Type

Detailed wiring diagram for the EVRC2A using VT type voltage inputs.

13.16. Control Cable Receptacle Pin Descriptions

Describes the pin functions for the control cable receptacle.

13.25. Communications

Details RS232, RS485/422, and Ethernet communication pin functions.