This switch enables the Local password. There is currently no local password protected functions. This
switch has no effect.
S2-3 Check Focus Delay Alarm Enable
This switch enables the ‘Check Focus Delay’ function. When this switch is ON the local and RSM/RCM
remote station alarm will sound prior to the show starting. This feature alerts the operator that the
show is about to start. The alarm will sound seven seconds before the show starts. This gives the
operator time to make any quick adjustments.
S2-4 Fire Stop Option Enable
This switch enables the Fire Stop option. This only applies to the older 39331 Booth and 39332 Single
termination boards that did not have a dedicated fire stop input. When this switch is ON the remote
stop input on these boards was treated as a fire stop.
S2-5 Undefined.
S2-6 Undefined.
S2-7 Event Logging Enable
This switch enables the Event Logging to Host function. When this switch is ON events are
automatically sent to the Host program as they occur. This applies only to the Host port 16000.
S2-8 Cinema Automation Interface (CAI) Enable
This switch enables the three CAI communications channels. When this switch is off, the CAI is
Disabled and the eCNA ignores incoming control data.
S3-1 Undefined.
S3-2 Undefined.
S3-3 Undefined.
S3-4 Undefined.
S3-5 Undefined.
S3-6 Defeat Check Focus Delay Alarm at Remote
This switch disables the ‘Check Focus Delay’ alarm at the RSM/RCM remote stations.
S3-7 Undefined
S3-8: Ethernet IP Defaults
This switch forces the default Ethernet TCP/IP settings. When this switch is ON, factory defaults will
be restored on a power up overwriting the user configured settings.
Ethernet default settings:
Duplex: Half
IP Address: 192.168.0.254
Subnet Mask: 255.255.255.0
Gateway IP: 0.0.0.0