Maintenance 8. Trouble Shooting
RC180 Rev.17 191
2269 Language ID is out of available range.
For available language ID, see the online
help. Review the program.
Specified D parameter value at the
parallel process is out of available
range.
Available D parameter value is from 0 to
100. Review the program.
The specified D
parameter value
2271 Arch number is out of available range.
Available arch number is from 0 to 7.
arch number
2272 Device No. is out of available range.
The specified number representing a
control device or display device is out of
available device
number, see the online help. Review
the program.
device number
2273 Output data is out of available range.
Available output data value is from 0 to
255. Review the program.
Output data
Asin argument is out of available
range. Range is from -1 to 1.
Review the program.
2275
Acos argument is out of available
range. Range is from -1 to 1.
Review the program.
2276 Sqr argument is out of available range. Review the program.
2277
Randomize argument is out of
available range.
Sin, Cos, Tan argument is out of
available range.
Review the program.
2280
Timeout period set by the TMOut
statement expired before the wait
condition was completed in the WAIT
statement.
Investigate the cause of timeout. Check
whether the set timeout period is proper.
Timeout period
2281
Timeout period set by TMOut
statement in WaitSig statement or
SyncLock statement expired.
Investigate the cause of timeout. Check
whether the set timeout period is proper.
Signal number
Timeout
period
2282
Timeout period set by TMOut
statement in WaitNet statement
expired.
Investigate the cause of timeout. Check
whether the set timeout period is proper.
Port number
Timeout
period
2283
Timeout.
Timeout at display device setting.
Reboot the controller.
2290 Cannot execute a motion command.
Cannot execut the motion command after
using the user function in the motion
command. Review the program.
2291 Cannot execute the OnErr command.
Cannot execute OnErr in the motiion
command when using user function in
the motion command. Review the
program.
2292
Cannot execute an I/O command while
the safeguard is open. Need Forced.
I/O command cannot be executed while
open. Review the
program.
Cannot execute an I/O command
during emergency stop condition. Need
I/O command cannot be executed during
emergency stop condition. Review the
2294
Cannot execute an I/O command when
an error has been detected. Need
Forced.
I/O command cannot be executed while
an error occurs. Review the program.
2295
Cannot execute this command from a
NoEmgAbort Task.
For details on inexecutable commands,
refer to the online help.