Maintenance 8. Trouble Shooting
RC180 Rev.17 197
Windows Communication Error.
Invalid answer.
Reboot the Controller.
Rebuild the project.
2472
Windows Communication Error.
Already initialized.
Reboot the Controller.
2473 Windows Communication Error. Busy.
Reboot the Controller.
Windows Communication Error. No
request.
Reboot the Controller.
Rebuild the project.
Windows Communication Error. Data
buffer overflow.
Reduce the data volume.
Review the program.
Windows Communication Error.
Failed to wait for event.
Reboot the Controller.
2477
Windows Communication Error.
Invalid folder.
Make sure the specified folder is correct.
2478
Windows Communication Error.
Invalid error code.
Rebuild the project.
2500
Specified event condition for Wait is
beyond the maximum count.
The maximum number of event
conditions is 8. Review the program.
Specified bit number in the Ctr
function was not setup with a CTReset
statement.
Task number is beyond the maximum
available number of the tasks that
can be executed simultaneously is 16.
Review the program.
Cannot execute Xqt when the specified
task number is already executing.
Review the program.
task number
2504
Task failure. Specified
already executing a parallel process.
Rebuild the project.
2505
Not enough data for Input statement
variable assignment.
Check the content of communication
data. Review the program.
Specified variable for the Input
beyond the maximum
count.
For OP, only one variable can be
specified. For other devices, up to 32
variables can be specified.
All counters are in use and cannot
setup a new counter with CTReset.
The available number of the counters
simultaneously is 16.
Review the program.
OnErr failure. Failed to process the
OnErr statement.
Rebuild the project.
2509
OnErr failure. Failed to process the
OnErr statement.
Rebuild the project.
2510 Specified I/O label is not defined.
The specified I/O label is not registered.
Check the I/O label file.
2511
SyncUnlock statement is used without
executing a previous SyncLock
statement. Review the program.
Review the program. Signal number
2512
SyncLock
The SyncLock statement cannot be
executed for the second time in a row.
Review the program.
Signal number
2513 Specified point label is not defined.
The specified point label is not
registered. Check the point file.
Failed to obtain the motor on time of
the robot.
Reboot the controller.
2515
Failed to configure the date or the
time.
Check whether a date and time is set