Maintenance 8. Trouble Shooting
RC180 Rev.17 235
Vision
7300
Vision Communication.
Server mode not supported.
Vision Communication.
Failed to read from the camera.
Check the connection with the camera.
Vision Communication.
Read data overflow.
Data exceeding the receive buffer was
received.
7304
Vision Communication.
Failed to open the Ethernet port.
Check the connection with the camera.
7305
Vision Communication.
Invalid IP address of camera.
Rebuild the project. Check the camera
Vision Communication. No
specification of Server/Client.
Vision Communication.
Failed to send to the camera.
Check the connection with the camera.
7308
Vision Communication.
The version of the connected camera is
7321
Vision Communication.
Camera setting has not been set.
Rebuild the project. Check the camera
Vision Communication.
Read timeout.
Check the connection with the camera.
Vision Communication.
Read invalid data.
Check the connection with the camera.
7324
Vision Communication.
Failed to send to the camera.
Check the connection with the camera.
7325
Vision Communication.
Connection is not completed.
Check the connection with the camera.
7326
Vision Communication.
Read data is too long.
Vision Communication.
Undefined vision sequence.
Check the sequence name.
7328
Vision Communication.
Camera setting has not been set.
Rebuild the project. Check the camera
7329
Vision Communication.
Rebuild the project. Check the camera
Vision Communication.
Failed to allocate memory.
Reduce the number of sequences,
objects, and calibration.
Vision Communication.
Out of max camera number.
Review the camera registration.
7342
Vision Communication.
Review the camera registration.
7343
Vision Communication.
VSet parameter is too long.
Review the names and string variables of
sequences, objects, and calibration.
7344
Vision Communication:
Too many parameters for VGet.
The number of specified variables is
exceeding 32. Reduce the number of
Vision Communication.
Not enough data for VGet statement
variable assignment.
Reboot the camera.
Check the version of the camera.
7346
Vision Communication.
Cannot execute a Vision statement
Execute the command from the program.
7500 Smart camera. Out of memory.
Initialize the camera.
Smart camera. Project does not exist.