Maintenance 8. Trouble Shooting
RC180 Rev.17 237
GUI Builder
No.
Message
Remedy
Note 1
Note 2
7600
Cannot execute a GUI Builder
statement from the command window.
GUI Builder commands are only available in
the program.
7602
GSet parameter is too long.
Correct the parameter to the proper length.
7603
Too many parameters for GGet.
Check the number of parameters.
7604
Not enough data for GGet statement
variable assignment.
Specify the variable.
7610
The event task cannot be executed.
System in pause state and
EventTaskType is Normal.
The system can be operated by changing
EventTaskType to NoPause
7611
The event task cannot be executed.
Safeguard is open and EventTaskType
is Normal.
The system can be operated by changing
EventTaskType to NoEmgAbort
7612
The event task cannot be executed.
Estop is active and EventTaskType is
not NoEmgAbort.
The system can be operated by changing
EventTaskType to NoEmgAbort
7613
The event task cannot be executed.
System in error state and
EventTaskType is not NoEmgAbort.
The system can be operated by changing
EventTaskType to NoEmgAbort
7650
Invalid property.
Specify the valid property.
7651
Invalid form.
Specify the valid form.
7652
Invalid control.
Specify the valid control.
7653
The specified form is already open.
Modify the program to avoid double launch.
7654
Event function does not exist.
Check the function name set for the event.
7655
The item does not exist.
Specify the valid item.
7656 Invalid property value.
Check the property value and specify the valid
value.
7847
MDL failure.
Failed to open the MDL file.
Reboot the controller.
Reinstall the firmware.
- -
7848
MDL failure.
Failed to read the MDL file.
Reboot the controller.
Reinstall the latest firmware version.
- -