DEPOLOX
®
Pool Operation
WT.050.570.000.DE.IM.0714 49
1.3
Redox settings
(menu 1.3)
Basic display Refer to main menu
Menu select Display of all available menus
Menu Redox Display of all available Redox settings
CEDOX parameters
setpoint within mV measuring range
setpoint ECO during ECO mode within mV measuring range
Xsh Neutral band for REDOX setpoint, 3 ... 50 mV
mV delay time Reaction time of the REDOX measurement
1...30 min.
Redox limit values
Min within measuring range
Max within measuring range
Hysteresis 001 ... 200 mV
Redox measuring range
Range-start 000 ... 400 mV
Range-end 500 ... 1000 mV