·60·
Operating manual
CNC 8055
CNC 8055i
2.
OPERATING IN JOG MODE
·TC· OPTION
SOFT: V02.2X
Tool calibration
2.7.4 Probe calibration (level 3)
This calibration level requires the purchase of the right software options purchased and the use of
a table-top probe.
This cycle may be used to calibrate the sides of the table-top probe, installed in a fixed position of
the machine whose sides parallel to the X and Z axes. The probe position must be defined in the
corresponding machine parameters (PRB*MIN, PRB*MAX).
To execute the cycle, a master tool of known dimensions will be used whose values have been
previously entered in the selected offset.
The data obtained in the calibration are updated directly in machine parameters PRB*MIN and
PRB*MAX. To do this, program P99998 must be set as OEM.
Defining the cycle data
The following data must be defined.
Tool number (T) and tool offset (D) used to define the dimensions of the master part.
Safety distance (Ds) for probe approach.
Probing feedrate (F).
Probe position.
In this zone, one must indicate whether the cycle assumes the probe position defined in the machine
parameters or the position defined in this zone. To select one of them, use the cursor to select the
"Machine parameters / Programmable parameters" field and press the two-color key.