OBID i-scan
®
System-Manual ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH Page 114 of 131 H60301-3e-ID-B.doc
9.3. Supported ISO15693 Host commands for I-Code EPC Transponders
The command codes listed in the following table support the various Transponder commands and
operations that are available for I-Code EPC Transponders.
Memory organization: 17 x 1 Byte = 136 Bit
Number of blocks 17 (user area: -)
Block size 1 byte
Command
Code
Function Mode Comment
non-ad-
dressed
addressed select
0x01 Inventory
√
---
0x02 Stay Quiet - - - -
0x18 Destroy
√√
--
0x22 Lock Multiple Blocks - - - -
0x23 Read Multiple Blocks - - - -
0x24 Write Multiple Blocks
√√
- - Block-Size =1 Byte
0x25 Select - - - -
0x26 Reset to Ready - - - -
0x27 Write AFI - - - -
0x28 Lock AFI - - - -
0x29 Write DSFID - - - -
0x2A Lock DSFID - - - -
0x2B Get System Information - - - -
0x2C
Get Multiple Block Security
Status
-- - -
0xA0 Read Config Block - - - -
0xA1 Write Config Block - - - -