6.1.5. [0x24] Write Multiple Blocks
This command writes one or more data blocks.
The supported ISO15693Host commands depend on the different ISO15693Transponder types,
which are described in chapter 9.1. Supported ISO15693 Host commands for ISO15693 Transpond-
ers.
REQUEST-DATA
4 5 (6...13) 6 / (14) 7 / (15) 8 / (16) 9...n / (17...n)
0x24 MODE UID DB-ADR DB-N DB-SIZE DB
Repeated DB-
N times
RESPONSE-DATA (STATUS = 0x03)
5
DB-ADR-E
RESPONSE-DATA (STATUS = 0x95)
5 6
ISO15693
ERROR
DB-ADR-E
MODE:
Bit: 7 6 5 4 3 2 1 0
Function 0 0 0 0 0 ADR
ADR:
b000 non-addressed
b001 addressed
b010 selected
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
DB-ADR:
Address of the first data block to be written to the Transponder. First block can be any value
between 0 and 255.
DB-N:
Number of data blocks to be written to the Transponder, starting at DB-ADR.
The maximum number of DB-N, depends on DB-Size and the interface receiver buffer size
RX-BUF. The maximum number of DB-N is:
(RX-BUF - 10 )/(DB-Size) Standard Protocol
(RX-BUF - 12 )/(DB-Size) Advanced Protocol

Table of Contents

Other manuals for Feig Electronic OBID i-scan ID ISC.PR101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic OBID i-scan ID ISC.PR101 and is the answer not in the manual?

Feig Electronic OBID i-scan ID ISC.PR101 Specifications

General IconGeneral
BrandFeig Electronic
ModelOBID i-scan ID ISC.PR101
CategoryOther
LanguageEnglish