OBID i-scan
®
System-Manual ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH Page 93 of 131 H60301-3e-ID-B.doc
8.4. Fujitsu ISO15693 MB89R118 Custom Commands
8.4.1. [0xA0] EAS Command
On EAS command reception, the transponder returns the response code repeated six times after the
specified flag (0x00) if the EAS bit is 1. If the EAS bit is 0 the transponder returns no response. The
EAS command can be executed only when the transponder is in the ready or selected state. The re-
sponse code value is 0x5A
REQUEST-DATA
5 6
0xA0 MODE
RESPONSE-DATA (STATUS = {0x95})
(5-10)
Response
Code(6 times)
MODE:
Bit: 7 6 5 4 3 2 1 0
Function - - - - - ADR
ADR:
ADR
b000 non-addressed
b001 addressed
b010 selected
Response-Code value:
This byte is only available if EAS bit is set. Value = {0x5A} 6 times sent,
else there is no response from tag.
8.4.2. [0xA1] Write EAS
This command writes the EAS bit.
REQUEST-DATA
5 6 (7-14) 7/15
0xA2 MODE UID DATA
RESPONSE-DATA (STATUS = {0x95})
5
ISO-ERROR
MODE:
Bit: 7 6 5 4 3 2 1 0
Function - - - - - ADR

Table of Contents

Other manuals for Feig Electronic OBID i-scan ID ISC.PR101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic OBID i-scan ID ISC.PR101 and is the answer not in the manual?

Feig Electronic OBID i-scan ID ISC.PR101 Specifications

General IconGeneral
BrandFeig Electronic
ModelOBID i-scan ID ISC.PR101
CategoryOther
LanguageEnglish