FEIG ELECTRONIC GmbH Page 92 of 131 H60301-3e-ID-B.doc
8.3.4. [0xA5] EAS Alarm
If the EAS bit is set to 1 the EAS response status 0x00 is returned from the transponder. This com-
mand is available in all modes (non-addressed , addressed and selected).Whether the reader receives
the sequence or not is shown to the host by setting the status byte.
REQUEST-DATA
5 6 (7-14)
0xA5 MODE UID
RESPONSE-DATA (STATUS = {0x95})
5
ISO-ERROR
MODE:
Bit: 7 6 5 4 3 2 1 0
Function - - - - - ADR
ADR:
ADR
b000 non-addressed
b001 addressed
b010 selected
UID:
Read-only serial number of the transponder. The UID is required only in the addressed mode.
ISO-ERROR:
ISO error code of transponder response. This byte is only available if STATUS = {0x95}.
Note:
If an error is detected or the EAS bit is set to “0” the transponder remains silent and the
status 0x01 will be sent to the host.
If EAS bit is set to “1” the status will be 0x00.

Table of Contents

Other manuals for Feig Electronic OBID i-scan ID ISC.PR101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic OBID i-scan ID ISC.PR101 and is the answer not in the manual?

Feig Electronic OBID i-scan ID ISC.PR101 Specifications

General IconGeneral
BrandFeig Electronic
ModelOBID i-scan ID ISC.PR101
CategoryOther
LanguageEnglish