OBID i-scan
®
System-Manual ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH Page 80 of 131 H60301-3e-ID-B.doc
8. [0xB1] Host commands for ISO15693 Custom and Proprietary Commands
This command sends custom defined commands to the Transponder.
Host → Reader
1 2 3 4 5...n-2 n-1,n
n COM-ADR [0xB1] MFR REQUEST-
DATA
CRC16
Host ← Reader
1 2 3 4 5...n-2 n-1,n
n COM-ADR [0xB1] STATUS RESPONSE-
DATA
CRC16
MFR:
Manufacturer code
MFR
0xXX
0x02 STMicroelectronics
0x04 Philips
0x05 Infineon
0x07 Texas Instruments
0x08 Fujitsu
0x16 EMMicroelectronic
0x17 KSW
Note:
If the Transponder type is not known the reader uses for the read multiple block command the
block size which is defined in 3.5. CFG4: Transponder Parameters (ISO-Blocksize)
REQUEST-DATA:
Manufacturer specific request
RESPONSE-DATA:
Manufacturer specific response
Notes:
• Data is only transferred if STATUS = 0x00, 0x83, 0x94, 0x95.
• This command is not available if the Scan-Mode is switched on.