6.1.7. [0x26] Reset to Ready
This command sets one Transponder to Ready State.
REQUEST-DATA
4 5 (6...13)
0x26 MODE UID
RESPONSE-DATA (STATUS = 0x95)
5
ISO15693
ERROR
MODE:
Bit: 7 6 5 4 3 2 1 0
Function 0 0 0 0 0 ADR
ADR:
b000 non-addressed
b001 addressed
b010 selected
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS =
0x95.
Note:
This command is only available for ISO15693 Transponders.