OBID i-scan
®
System-Manual ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH Page 90 of 131 H60301-3e-ID-B.doc
8.3. Philips ISO15693 I-Code SLI Custom Commands
8.3.1. [0xA2] Set EAS
This command sets the EAS bit to 1.
REQUEST-DATA
5 6 (7-14)
0xA2 MODE UID
RESPONSE-DATA (STATUS = {0x95})
5
ISO-ERROR
MODE:
Bit: 7 6 5 4 3 2 1 0
Function - - - - - ADR
ADR:
ADR
b000 non-addressed
b001 addressed
b010 selected
UID:
Read-only serial number of the transponder. The UID is required only in the addressed mode.
ISO-ERROR:
ISO error code of transponder response. This byte is only available if STATUS = {0x95}.
8.3.2. [0xA3] Reset EAS
This command sets the EAS bit to 0.
REQUEST-DATA
5 6 (7-14)
0xA3 MODE UID
RESPONSE-DATA (STATUS = {0x95})
5