EasyManuals Logo

Feig Electronic OBID i-scan ID ISC.PR101 User Manual

Feig Electronic OBID i-scan ID ISC.PR101
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
OBID i-scan
®
System-Manual ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH Page 43 of 131 H60301-3e-ID-B.doc
3.11. CFG48: Bluetooth
The configuration blocks CFG17 .. 47 are reserved for future use.
Byte 0 1 2 3 4 5 6
Contents 0x00 0x00 Bluetooth_name_suffix Blue-
tooth_Key
Default 0x31 0x30 0x31 0x42 0x31
Byte 7 8 9 10 11 12 13
Contents Bluetooth_Key 0x00 0x00 0x00 Power On-
Time [min.]
Default 0x32 0x33 0x34 0x03
Bluetooth_name_suffix:
Defines the name-suffix of Bluetooth-modul. The whole name of Bluetooth-modul is:
OBID-PRHByte2Byte3Byte4Byte5. (Default: OBID-PRH101B)
Bluetooth_Key:
Defines the authentification pin of Bluetooth-modul
Power-On Time (value in minutes):
Defines the duration of power-on time after the last inventory (retrigger).
Durations between 1min.10min. possible (Default: 3min.).