OBID i-scan
®
System-Manual ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH Page 117 of 131 H60301-3e-ID-B.doc
ANNEX B: Time Behavior of the Asynchronous Interface
The execution times of the asynchronous interface depend on:
The extent of the data that needs to be read or written
Type and amount of Transponders supported by the Reader
Position of the Transponder at the time of the request
Probable local electromagnetic interference present
The success or failure of the request
min. typ. max. Unit
I-Code 1
EE-Parameter change
1 Block (16 Bytes)
all ( 8 ) Blocks
5 22,5
180
300
600
ms
ms
7.1. [0x1B] Reset
QUIET Bit (only I-Code
1 Transponders)
5 5,1 - 300
ms
Fehler! Kein gültiges
Resultat für Tabelle.
5,1
ms
6.1. [0xB0] Host com-
mands for ISO15693
Mandatory and Optional
Commands
5
12
ms
8. [0xB1] Host com-
mands for ISO15693
Custom and Proprietary
Commands
5
12
ms
8.6. [0xBF] ISO15693
Transparent Command
5
12
ms
1
see ANNEX C: Time Behavior of ISO15693 Host Commands for details
2
as configured in 3.2. CFG1: Interface TR-RESPONSE-TIME

Table of Contents

Other manuals for Feig Electronic OBID i-scan ID ISC.PR101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic OBID i-scan ID ISC.PR101 and is the answer not in the manual?

Feig Electronic OBID i-scan ID ISC.PR101 Specifications

General IconGeneral
BrandFeig Electronic
ModelOBID i-scan ID ISC.PR101
CategoryOther
LanguageEnglish