OBID i-scan
®
System-Manual ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH Page 117 of 131 H60301-3e-ID-B.doc
ANNEX B: Time Behavior of the Asynchronous Interface
The execution times of the asynchronous interface depend on:
• The extent of the data that needs to be read or written
• Type and amount of Transponders supported by the Reader
• Position of the Transponder at the time of the request
• Probable local electromagnetic interference present
• The success or failure of the request
min. typ. max. Unit
I-Code 1
EE-Parameter change
1 Block (16 Bytes)
all ( 8 ) Blocks
5 22,5
180
300
600
ms
ms
7.1. [0x1B] Reset
QUIET Bit (only I-Code
1 Transponders)
5 5,1 - 300
ms
Fehler! Kein gültiges
Resultat für Tabelle.
5,1
ms
6.1. [0xB0] Host com-
mands for ISO15693
Mandatory and Optional
Commands
5
12
ms
8. [0xB1] Host com-
mands for ISO15693
Custom and Proprietary
Commands
5
12
ms
8.6. [0xBF] ISO15693
Transparent Command
5
12
ms
1
see ANNEX C: Time Behavior of ISO15693 Host Commands for details
2
as configured in 3.2. CFG1: Interface TR-RESPONSE-TIME