6.1.10. [0x29] Write DSFI
This command writes the DSFID to one ore more Transponders.
The supported ISO15693 Host commands depend on the different ISO15693 Transponder types,
which are described in chapter 9.1. Supported ISO15693 Host commands for ISO15693 Transpon-
ders.
REQUEST-DATA
4 5 (6...13) 6 / (14)
0x29 MODE UID DSFID
RESPONSE-DATA (STATUS = 0x95)
5
ISO15693
ERROR
MODE:
Bit: 7 6 5 4 3 2 1 0
Function 0 0 0 0 0 ADR
ADR:
b000 non-addressed
b001 addressed
b010 selected
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
DSFID:
Data Storage Format Identifier of the Transponder.
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS =
0x95.
Note:
This command is only available for ISO15693 Transponders.

Table of Contents

Other manuals for Feig Electronic OBID i-scan ID ISC.PR101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic OBID i-scan ID ISC.PR101 and is the answer not in the manual?

Feig Electronic OBID i-scan ID ISC.PR101 Specifications

General IconGeneral
BrandFeig Electronic
ModelOBID i-scan ID ISC.PR101
CategoryOther
LanguageEnglish