EasyManuals Logo

Feig Electronic OBID i-scan ID ISC.PR101 User Manual

Feig Electronic OBID i-scan ID ISC.PR101
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #121 background imageLoading...
Page #121 background image
OBID i-scan
®
System-Manual ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH Page 121 of 131 H60301-3e-ID-B.doc
ANNEX D: Index of Status Bytes
Hex-value
General
0x00
OK:
Data / parameters have been read or stored without error
Control command has been executed
Hex-value
Transponder Status
0x01
No Transponder:
No Transponder is located within the detection range of the Reader.
The Transponder in the detection range has been switched to mute.
The communication between Reader and Transponder has been interfered and the Reader
is not able to read the Transponder anymore.
0x02
Data False:
CRC16 data error on received data.
0x03
Write-Error:
Negative plausibility check of the written data:
Attempt to write on a read-only storing-area.
Too much distance between Transponder and Reader antenna.
Attempt to write in a noise area.
0x04
Address-Error:
The required data are outside of the logical or physical Transponder-address area:
The address is beyond the max. address space of the Transponder.
The address is beyond the configured address space of the Transponder.
0x05
Wrong Transponder-type:
This command is not applicable at the Transponder:
Attempt to write on or read from a Transponder.
A special command is not applicable to the Transponder.

Table of Contents

Other manuals for Feig Electronic OBID i-scan ID ISC.PR101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic OBID i-scan ID ISC.PR101 and is the answer not in the manual?

Feig Electronic OBID i-scan ID ISC.PR101 Specifications

General IconGeneral
BrandFeig Electronic
ModelOBID i-scan ID ISC.PR101
CategoryOther
LanguageEnglish