EasyManuals Logo

Feig Electronic OBID i-scan ID ISC.PR101 User Manual

Feig Electronic OBID i-scan ID ISC.PR101
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
OBID i-scan
®
System-Manual ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH Page 99 of 131 H60301-3e-ID-B.doc
EOF-PULSE-DELAY:
EOF Pulse delay is used in write operations with ISO15693 write option “1”. EOF to define
the in response delay for Transponder response (ISO15693: t1)
e.g. ISO15693 maximum value: 0x846A * 590ns = 20ms
REQUEST-DATA:
Complete Transponder request without SOF, CRC16 and EOF
Note:
The read and write option FLAGS in the REQUEST-DATA must correspond to the
MODE Byte in the request protocol. Reader is always forcing the command in the
way specified by MODE Byte in the request protocol
RESPONSE-DATA:
Complete Transponder response without SOF and EOF. A CRC16 check is performed inside
the Reader. However the Transponder CRC16 is transferred with the response data.
Notes:
Data is only transferred if STATUS = 0x00, 0x83, 0x94, 0x95.
The response data ever contain the in RSP-LENGTH defined number of data bytes.
Note:
This command is only available for ISO15693 Transponders.
This command is not available if the Scan-Mode is witched on.

Table of Contents

Other manuals for Feig Electronic OBID i-scan ID ISC.PR101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic OBID i-scan ID ISC.PR101 and is the answer not in the manual?

Feig Electronic OBID i-scan ID ISC.PR101 Specifications

General IconGeneral
BrandFeig Electronic
ModelOBID i-scan ID ISC.PR101
CategoryOther
LanguageEnglish