5. Parameter
5−74
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Measuring system length (sensor length)
PNU PNU: 1111 Index: 1 Max index: 1 Class: Var Data type: int32
Values Unit: Length (index = 2)
Linear drive Semi−rotary drive
Dimension Default Minimum Maximum Dimension Default Minimum Maximum
SI 0.01 mm 0 5.000 1.000.000 0,1 ° 0 500 100.000
Imperial 0.01 mm 0 5.000 1.000.000 0,1 ° 0 500 100.000
With the DGCI and the DNCI the cylinder length and the measuring system length need to tally.
The sensor length is stored in the sensor interface with the DGCI.
o The parameter value cannot be changed.
ý Writing permissible only in commissioning/parametrising mode with disabled controller.
o This parameter can be written by FCT without higher−order controller.
ý After writing, controller recalculation is carried out.
Measuring system serial number (sensor serial number)
PNU PNU: 1112 Index: 1
Max index: 1 Class: Var Data type: bitarray
Values Default: 0000 0000 0000 0000 0000 0000 0000 0000
Write:
Each sensor interface has a unique serial number.
The serial number can be used to identify exchanged hardware, see appendix A.3.
o The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
o This parameter can be written by FCT without higher−order controller.
o After writing, controller recalculation is carried out.

Table of Contents

Other manuals for Festo CPX-CMAX-C1-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CPX-CMAX-C1-1 and is the answer not in the manual?

Festo CPX-CMAX-C1-1 Specifications

General IconGeneral
BrandFesto
ModelCPX-CMAX-C1-1
CategoryController
LanguageEnglish

Related product manuals