B. Basic controlling principles
B−11
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
B.2.2 Dimension reference system with incremental measuring system
System of units with incremental measuring system
1
bc
PZ
d
e
TP/AP USE
2
Positions increasing in size, positive"
travel, right−hand" travel
CZ/AZ
REF
LSE
a
CZ Cylinder zero point
a Offset axis zero point
offset (increm sensor:
REF Reference point, stop
o
ff
set
(i
ncrem. sensor:
to the reference point)
AZ Axis zero point b Offset project zero point
PZ Project zero point c Offset target/actual posi
tion
LSE Lower software end position d, e Offset software end posi
tions:
USE Upper software end position 1 Effective stroke
TP, AP Target/actual position 2 Cylinder/axis length
Tab.B/9: Dimension reference system for pneumatic drives with incremental measuring
system (example of homing negative stop)
The axis zero point always has to be on the cylinder zero
point! This is necessary because the controller requires the
absolute piston position within the cylinder.
This means that the vector a must always be specified.

Table of Contents

Other manuals for Festo CPX-CMAX-C1-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CPX-CMAX-C1-1 and is the answer not in the manual?

Festo CPX-CMAX-C1-1 Specifications

General IconGeneral
BrandFesto
ModelCPX-CMAX-C1-1
CategoryController
LanguageEnglish

Related product manuals