B. Basic controlling principles
B−24
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
B.6.1 Proceed as follows if the compressed air supply is unstable:
If your compressed air supply does not reliably fulfil the re
quirements (tolerance of +/− 1 bar in operation), although a
compressed air reservoir has been installed (see CMAX sys
tem description), the maximum values for acceleration and
deceleration ascertained during identification may, under
circumstances, not be reached.
This may result e.g. in overswing,
if the supply pressure re
quired for deceleration is not available.
In order to avoid such overstressing, you can reduce the dy
namics of the system. In order to do this proceed as follows:
1. Ascertain the lowest static supply pressure available for
positioning in your compressed air network.
2. Lower the supply pressure statically
to this level.
3. Now carry out the dynamic identification travel again.
4. When system identification is concluded, increase the
supply pressure again to the value set in the application
data.

Table of Contents

Other manuals for Festo CPX-CMAX-C1-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CPX-CMAX-C1-1 and is the answer not in the manual?

Festo CPX-CMAX-C1-1 Specifications

General IconGeneral
BrandFesto
ModelCPX-CMAX-C1-1
CategoryController
LanguageEnglish

Related product manuals