5. Parameter
5−59
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
5.4.7 Setpoint values for jog mode
Jog mode slow speed
PNU PNU: 530 Index: 1 Max index: 1 Class: Var Data type: int32
Values Unit: Speed (index = 6)
Linear drive Semi−rotary drive
Dimension Default Minimum Maximum Dimension Default Minimum Maximum
SI 0,001 m/s 50 10 500 1 °/s 50 10 500
Imperial 0.01 ft/s 15 3 164 1 °/s 50 10 500
Slow speed for jogging.
o The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
o This parameter can be written by FCT without higher−order controller.
o After writing, controller recalculation is carried out.
Jog mode fast speed
PNU PNU: 531 Index: 1 Max index: 1 Class: Var Data type: int32
Values Unit: Speed (index = 6)
Linear drive Semi−rotary drive
Dimension Default Minimum Maximum Dimension Default Minimum Maximum
SI 0,001 m/s 200 10 10.000 1 °/s 200 10 10.000
Imperial 0.01 ft/s 65 3 3.281 1 °/s 200 10 10.000
Maximum speed after expiration of the jogging slow speed period.
Depending on PNU 521:01, the corresponding default value is used instead, if necessary.
o The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
o This parameter can be written by FCT without higher−order controller.
o After writing, controller recalculation is carried out.