A. Notes on commissioning and service
A−28
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
A.4 Programming flow charts
The following section provides flow charts for CMAX control
via I/O for typical applications.
A.4.1 Create ready status
Requirements
Valve operating voltage and load voltage OFF.
Fieldbus master is ready for communication, so communi
cation is established as soon as the CPX terminal is
switched on. If this is not the case, additional time must
be allowed for change of the byte order after establish
ment of communication.
Notes
All enabling bits (enable,
stop, brake) can be set right
from the beginning and simultaneously. Correspondingly,
feedback can be evaluated simultaneously.
When exchanging components, the movement test is
reset automatically, if applicable. The movement test
status should therefore be checked before switching on
and the test be re−run automatically or user−guided, if
required.
Setting the operating mode should
be done in a separate
module of the control at a central position. See also sec
tion A.4.4.
If the CMAX reports a faults, depending on this fault, not
all of the expected status signals can be indicated. Evalu
ation of SCON.ENABLED or SCON.OPEN, for example,
should then be aborted.

Table of Contents

Other manuals for Festo CPX-CMAX-C1-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CPX-CMAX-C1-1 and is the answer not in the manual?

Festo CPX-CMAX-C1-1 Specifications

General IconGeneral
BrandFesto
ModelCPX-CMAX-C1-1
CategoryController
LanguageEnglish

Related product manuals