5. Parameter
5−94
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Notes on PNU 1190:
Behaviour on delivery or after resetting the axis or
device data: The recognized configuration is not auto
matically included in the setpoint configuration. Instead
the setpoint configuration is filled with 0. The setpoint
configuration must be written in a way that is compatible
with the actual configuration.
Behaviour upon
normal star t: If the recognized hardware
does not correspond with the setpoint configuration, this
will trigger error handling. A decision is made as to
whether the change must lead to a warning or a fault.
Possibly the controller will not be activated.
If an identification is performed successfully, the serial
numbers are adopted
so that the warning Exchanged
hardware" is no longer issued the next time the device is
switched on.
The piston rod diameter is not provided by the sensor
interface. The actual configuration always contains the
value0. However, since this is a valid value for rodless
drives, the value0 is not consider ed as not recognized"
in the case of the piston rod diameter. Therefore no
SETPOINT−ACTUAL check is performed after switching on.