6. Parametrisation
6−10
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Carry out parametrising
1. Step: Prepare parametrising with No request"
Allocation of the control bytes (step 1)
Bit B7 B6 B5 B4 B3 B2 B1 B0
CCON
OPM2 OPM1 LOCK RESET BRAKE STOP ENABLE
Byte 1
1 1 1 x x x 0 1
Subindex
Subindex of the parameter to be transmitted =0
Byte 2
0 0 0 0 0 0 0 0
Para
PNU = 0
meter
0 0 0 0 0 0 0 0
identifier
ReqID = 0 PNU = n. r. (0000 0000 0000b)
y
e
+
0 0 0 0 0 0 0 0
Para
meter
value
Byte 5...8
Value of the parameter to be transmitted = 0
Waiting for feedback from CMAX: No request".
Allocation of the status bytes (step 1)
Bit B7 B6 B5 B4 B3 B2 B1 B0
SCON
OPM2 OPM1 FCT_MMI 24VL FAULT WARN OPEN ENABLED
Byte 1
1 1 0 1 0 0 0 1
Subindex
Subindex of the transmitted parameter: not relevant
Byte 2
0 0 0 0 0 0 0 0
Para
PNU = not relevant
meter
0 0 0 0 0 0 0 0
identifier
ResID = 0 (0000 b) PNU = not relevant
y
e
+
0 0 0 0 0 0 0 0
Para
meter
value
Byte 5...8
Value of the transmitted parameter: not relevant