A. Notes on commissioning and service
A−23
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Defined error codes
Message
Effect
E01
More than one component (cylinder and
valve) were replaced for another.
Identification must be reset and executed
anew once the setpoint configuration has
been adjusted
Cylinder (type, length, diameter) does not
correspond to the setpoint configuration.
been adjusted.
Or reset to previous status, as required.
Measuring system (type, length) does not
correspond to the setpoint configuration.
Valve (type) does not correspond to the set
point configuration.
W08 A component (cylinder, sensor or valve) was
replaced for another.
Identification should be repeated, but oper
ation is still possible.