FIMER_PVS-175-TL A.1 Version_Product manual_EN_RevC-
F
113
The parameters related to the customer wireless network (setted on the router) that must be known
and to be entered during this step are:
• IP Settings (DHCP or Static):
If you select the DHCP function (default setup) the
router will automatically assign a dynamic IP address to
the inverter whenever it tries to connect to the user
network.
With Static, the user can assign a fixed IP address to
the system. The data which has to be entered in order
for IP static address assigning to take place will appear.
Complete the additional fields at the bottom of the
screen (all the fields are mandatory with the exception
of the secondary DNS server).
• Available networks (SSID):
Identify and select your own (customer) wireless
network from all those shown in the SSID field (you can
carry out a new search of the networks that can be
detected with the Update button ).
Once the network has been selected, confirm.
• Password (Wireless network password):
Enter the password for the destination network (if
necessary) and start the connection attempt (it will take
a few seconds).
• Click on “Connect” button.
•
A message will ask for confirmation. Click “Next” to
connect the inverter to the wireless network.