9 Measurement
9.4 Displaying measured values FLUXUS F60*
2017-10-16, UMFLUXUSF60xV5-0EN
108
The measured values of the physical quantity selected in the program branch Output
Options can be displayed in the lower line:
Press key during the measurement to change the display in the upper line, press
key to change the display in the lower line.
The character * indicates that the displayed value (here: flow velocity) is not the selected
physical quantity.
Status line
Important information of the running measurement is summarized in the status line.
Quality and precision of the running measurement can be evaluated.
Press key during the measurement to scroll through the upper line to the status line.
display explanation
12.3 m/s flow velocity
1423 m/s sound speed
124 m3/h mass flow rate
15 m3/h volumetric flow rate
12 kW heat flow
Fig. 9.4: Display of the status line
A:Flow Velocity
* 2.47 m/s
A: S3 Q9 c RT F