21 Heat flow measurement
21.6 Steam in inlet FLUXUS F60*
2017-10-16, UMFLUXUSF60xV5-0EN
216
21.6.1 Activation/deactivation
Select Special Funct.\SYSTEM settings\Dialogs/Menus\Steam in inlet.
Press ENTER.
Select on to deactivate Steam in inlet. The state of aggregation of the fluid is de-
termined by means of the supply pressure and the supply temperature of the fluid.
Select off to deactivate Steam in inlet. The fluid is then always considered to be
liquid in the supply line.
Press ENTER.
•If Steam in inlet is activated, the supply pressure has to be entered in the program
branch Parameter.
Enter the supply pressure.
Press ENTER.
Special Funct.\SYSTEM settings\Dialogs/Menus\Steam in inlet
Special Funct.\...\Steam in inlet\Inlet pressure
Notice!
The menu item Steam in inlet will always be displayed independently of the
selected physical quantity. However, the supply pressure will only be used for the
heat flow measurement.