8. Repeat steps 4 and 5 to take measurements in at least three clock positions over at least
70° of rotation. (Taking more position measurements improves the reliability of results.)
9. When enough measurement points over at least 70° rotation have been taken, tap to
stop measurement.
10. Tap to view cardan alignment results.
Evaluation and alignment
Offset has no real influence in the alignment condition but any angularity at the rotational axes
must be corrected.
As only angularity must be corrected in cardan shaft alignment, results displayed show only
foot values for one pair of feet. Angularity may be presented in mrad or degrees. Cardan shaft
units are set under default settings in configuration.
Note
ROTALIGNtouch EX 149
On-board help

Table of Contents