5.2 Function Code Tables
5-3
Chapter 5 Function Code
Drive control
The FRENIC-MEGA runs under any of the following drive controls. Some functional codes assigned apply
exclusively to the specific drive control, which is indicated by letters Y (Applicable) and N (Not applicable) in
the "Drive control" column of the functional code tables.
Table 5.2-3
Abbreviation in
"Drive control"
column in
function code
tables
Control target (H18) Drive control (F42)
V/f
V/f control
Dynamic torque vector control
PG V/f
V/f control with speed sensor
Dynamic torque vector control with speed sensor
w/o PG Vector control without speed sensor
w/ PG
Speed (Frequency for
V/f and PG V/f)
Vector control with speed sensor
Torque control Torque Vector control with/without speed sensor
For details about the drive control, refer to the description of F42 "Drive Control Selection 1."
The FRENIC-MEGA is a general-purpose inverter whose operation is customized by
frequency-basis function codes, with drive controls equivalent to conventional inverters. Unde
the speed-basis drive control, however, the control target is a motor speed, not a frequency, so
convert the frequency to the motor speed according to the following equation.
Equation: Motor speed (r/min) = 120 x Frequency (Hz) / Number of poles