5.2 Function Code Tables
5-17
Function
Code Tables
F codes
E codes
C codes
P codes
H codes
A codes
b codes
r codes
J codes
d codes
U codes
y codes
Chapter 5 Function Code
Drive control
Code Name Data setting range
Change
when
running
Data
copying
Default
setting
V/f
PG
V/f
w/o
PG
w/
PG
To rq ue
control
Refer to
page:
b18 Motor 3 (Auto-tuning) 0: Disable
1: Tune while the motor stops. (%R1, %X and rated slip frequency)
2: Tune the motor while it is rotating under V/f control (%R1, %X and
rated slip frequency, no-load current, magnetic saturation factors 1
to 5, magnetic saturation extension factors "a" to "c")
3: Tune the motor while it is rotating under vector control (%R1, %X
and rated slip frequency, no-load current, magnetic saturation factors
1 to 5, magnetic saturation extension factors "a" to "c"; enabled
under vector control only)
N N 0 Y Y Y Y Y
b19 (Online tuning) 0: Disable, 1: Enable Y Y 0 Y N N N N
b20 (No-load current) 0.00 to 2000 A N Y1, Y2 *6 Y Y Y Y Y
b21 (%R1) 0.00 to 50.00% Y Y1, Y2 *6 Y Y Y Y Y
b22 (%X) 0.00 to 50.00% Y Y1, Y2 *6 Y Y Y Y Y
b23 (Slip compensation gain for driving) 0.0 to 200.0% Y* Y 100.0 Y Y Y Y N
b24 (Slip compensation response time) 0.01 to 10.00 s Y Y1, Y2 0.12 Y Y N N N
b25 (Slip compensation gain for braking) 0.0 to 200.0% Y* Y 100.0 Y Y Y Y N
b26 (Rated slip frequency) 0.00 to 15.00 Hz N Y1, Y2 *6 Y Y Y Y N
b27 (Iron loss factor 1) 0.00 to 20.00% Y Y1, Y2 *6 Y Y Y Y Y
b28 (Iron loss factor 2) 0.00 to 20.00% Y Y1, Y2 0.00 Y Y Y Y Y
b29 (Iron loss factor 3) 0.00 to 20.00% Y Y1, Y2 0.00 Y Y Y Y Y
b30 (Magnetic saturation factor 1) 0.0 to 300.0% Y Y1, Y2 *6 Y Y Y Y Y
b31 (Magnetic saturation factor 2) 0.0 to 300.0% Y Y1, Y2 *6 Y Y Y Y Y
b32 (Magnetic saturation factor 3) 0.0 to 300.0% Y Y1, Y2 *6 Y Y Y Y Y
b33 (Magnetic saturation factor 4) 0.0 to 300.0% Y Y1, Y2 *6 Y Y Y Y Y
b34 (Magnetic saturation factor 5) 0.0 to 300.0% Y Y1, Y2 *6 Y Y Y Y Y
b35 (Magnetic saturation extension factor
"a")
0.0 to 300.0%
Y Y1, Y2 *6 Y Y Y Y Y
b36 (Magnetic saturation extension factor
"b")
0.0 to 300.0%
Y Y1, Y2 *6 Y Y Y Y Y
b37 (Magnetic saturation extension factor
"c")
0.0 to 300.0%
Y Y1, Y2 *6 Y Y Y Y Y
b39 Motor 3 Selection 0: Motor characteristics 0 (Fuji standard motors, 8-series)
1: Motor characteristics 1 (HP rating motors)
2: Motor characteristics 2 (Fuji motors exclusively designed for vector
control)
3: Motor characteristics 3 (Fuji standard motors, 6-series)
4: Other motors
N Y1, Y2 0 Y Y Y Y Y
b40 Slip Compensation 3 (Operating
conditions)
0: Enable during ACC/DEC and at base frequency or above
1: Disable during ACC/DEC and enable at base frequency or above
2: Enable during ACC/DEC and disable at base frequency or above
3: Disable during ACC/DEC and at base frequency or above
N Y 0 Y Y N N N
b41 Current Fluctuation Damping Gain
for Motor 3
0.00 to 0.40 Y Y 0.20 Y Y N N N
b42 Motor/Parameter Switching 3 (Mode
selection)
0: Motor (Switch to the 3rd motor)
1: Parameter (Switch to b codes)
N Y 0 Y Y Y Y Y 5-211
b43 Speed Control 3 (Speed command
filter) 0.000 to 5.000 s Y Y 0.020 N Y Y Y N
b44 (Speed detection filter) 0.000 to 0.100 s Y* Y 0.005 N Y Y Y N
b45 P (Gain) 0.1 to 200.0 times Y* Y 10.0 N Y Y Y N
b46 I (Integral time) 0.001 to 9.999 s
999: Integration disabled
Y Y 0.100 N Y Y Y N
b47 (Feed Forward Gain) 0.00 to 99.99 s Y* Y 0.00 N N Y Y N
b48 (Output filter) 0.000 to 0.100 s Y Y 0.002 N Y Y Y N
b49 (Notch filter resonance frequency) 1 to 200 Hz Y Y 200 N N N Y N
b50 (Notch filter attenuation level) 0 to 20 dB Y Y 0 N N N Y N
b51 Cumulative Motor Run Time 3 0 to 9999
(The cumulative run time can be modified or reset in units of 10 hours.)
N N - Y Y Y Y Y
b52 Startup Counter 3 Indication for replacement (0000 to FFFF (hex.)) Y N - Y Y Y Y Y
b53 Motor 3 (%X correction factor 1) 0 to 300% Y Y1, Y2 100 Y Y Y Y Y
b54 (%X correction factor 2) 0 to 300% Y Y1, Y2 100 Y Y Y Y Y
b55 (Torque current under vector control) 0.00 to 2000 A N Y1, Y2 *6 N N Y Y Y
b56 (Induced voltage factor under vector
control)
50 to 100%
N Y1, Y2 *6 N N Y Y Y
b57 Reserved *9 0.000 to 20.000 s Y Y1, Y2 *6 - - - - -