5.2 Function Code Tables
5-22
Drive control
Code Name Data setting range
Change
when
running
Data
copying
Default
setting
V/f
PG
V/f
w/o
PG
w/
PG
To rq ue
control
Refer to
page:
d 51 Reserved *9 0 to 500 N Y *10 - - - - - 5-247
d 52 Reserved *9 0 to 500 N Y *10 - - - - -
d 53 Reserved *9 0 to 500 N Y *10 - - - - -
d 54 Reserved *9 0 to 500 N Y *10 - - - - -
d 55 Reserved *9 0000 to 00FF (hex.) N Y 0000 - - - - -
d 59 Command (Pulse Rate Input)
(Pulse input format)
0: Pulse train sign/Pulse train input
1: Forward rotation pulse/Reverse rotation pulse
2: A/B phase with 90 degree phase shift
N Y 0 Y Y Y Y Y 5-62
5-247
d 60 (Encoder pulse resolution) 0014 to 0E10 (hex.)
(20 to 3600)
N Y 0400
(1024)
N Y N Y N 5-247
d 61 (Filter time constant) 0.000 to 5.000 s Y Y 0.005 Y Y Y Y Y
d 62 (Pulse count factor 1) 1 to 9999 Y *12 Y 1 Y Y Y Y Y
d 63 (Pulse count factor 2) 1 to 9999 Y
*12
Y 1 Y Y Y Y Y
d 67 Starting Mode (Auto search) 0: Disable
1: Enable (Only at restart after momentary power failure)
2: Enable (At normal start and at restart after momentary power failure)
N Y 2 N N Y N Y 5-184
d 68 Reserved *9 0.0 to 10.0 Hz N Y 4.0 - - - - - 5-247
d 69 Reserved *9 30.0 to 100.0 Hz Y Y 30.0 - - - - -
d 70 Speed Control Limiter 0.00 to 100.00% Y Y 100.00 N Y N N N 5-248
d 71 Synchronous Operation
(Main ASR gain)
0.00 to 1.50 times Y Y 1.00 N Y N Y N 5-247
d 72 (APR P gain) 0.00 to 200.00 times Y Y 15.00 N Y N Y N
d 73 (APR output + side limitter) 20 to 200%; 999: No limitter Y Y 999 N Y N Y N
d 74 (APR output - side limitter) 20 to 200%; 999: No limitter Y Y 999 N Y N Y N
d 75 (Z phase shift agreement gain) 0.00 to 10.00 times Y Y 1.00 N Y N Y N
d 76 (Synchronous offset angle) 0 to 359 deg Y Y 0 N Y N Y N
d 77 (Synchronization completion
detection angle)
0 to 100 deg Y Y 15 N Y N Y N
d 78 (Deviation excess detection width) 0 to 65535 (in the unit of 10 pulses)
(For a set value of 10000 or above,
the first four digits are indicated in the unit of 100 pulses)
Y Y 65535
*11
N Y N Y N
d 81 Reserved *9 0 to 1 Y Y 1 - - - - -
d 82 Magnetic flux weakening control
(Vector control without speed sensor)
0: Disabled
1: Enabled
Y Y 1 N N N N Y 5-248
d 83 Magnetic flux weakening lower limit
(Vector control without speed sensor)
10 to 70% Y Y 40% N N N N Y
d 84 Reserved *9 0 to 20 dB Y Y 5dB - - - - -
d 85 Reserved *9 0 to 200% Y Y 95% - - - - -
d 86 ACC/DEC Filter Time Constant 0.000 to 5.000 s Y Y 0.000 Y N N N N 5-248
d 90 Magnetic flux level during
deceleration
(under vector control)
100 to 300% Y Y 150% N N Y Y N 5-248
d 91 Reserved *9 0.00 to 200, 999 Y Y 999 - - - - -
d 92 Reserved *9 0.00 to 3.00 Y Y 0.00 - - - - -
d 98 Reserved *9 0000 to FFFF (hex.) Y Y 0000 Y Y N N N
0 to 31
Bit 0: Reserved *9 - - - - -
Bit 1: Reserved *9 - - - - -
Bit 2: Reserved *9 - - - - -
Bit 3: JOG operation from communications (0: Disabled; 1: Enabled) Y Y Y Y N
d 99 Extended Function 1
Bit 4: Reserved *9
Y Y 0
- - - - -
5-248
*9 These function codes are reserved for particular manufacturers. Do not access these function codes.
*10 The factory default differs depending upon the inverter's capacity. 5 for inverters with a capacity of 3.7 kW or below; 10 for
those with 5.5 kW to 22 kW; 20 for those with 30 kW or above
*11 On a standard keypad, "6553" is indicated in the LED display, and the "x10" LED lamp goes on.
*12 Change when running is not possible with the ROM version 3700 or earlier.