EasyManua.ls Logo

Galil DMC-4040 - Independent Jogging; Command Summary - Jogging

Galil DMC-4040
284 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 6.1: Velocity Profiles of XYZ
Notes on Figure 6.1: The X and Y axis have a ‘trapezoidal’ velocity profile, while the Z axis has a ‘triangular’
velocity profile. The X and Y axes accelerate to the specified speed, move at this constant speed, and then
decelerate such that the final position agrees with the command position, PR. The Z axis accelerates, but before the
specified speed is achieved, must begin deceleration such that the axis will stop at the commanded position. All 3
axes have the same acceleration and deceleration rate, hence, the slope of the rising and falling edges of all 3
velocity profiles are the same.
Independent Jogging
The jog mode of motion is very flexible because speed, direction and acceleration can be changed during motion.
The user specifies the jog speed (JG), acceleration (AC), and the deceleration (DC) rate for each axis. The direction
of motion is specified by the sign of the JG parameters. When the begin command is given (BG), the motor
accelerates up to speed and continues to jog at that speed until a new speed or stop (ST) command is issued. If the
jog speed is changed during motion, the controller will make a accelerated (or decelerated) change to the new speed.
An instant change to the motor position can be made with the use of the IP command. Upon receiving this
command, the controller commands the motor to a position which is equal to the specified increment plus the current
position. This command is useful when trying to synchronize the position of two motors while they are moving.
Note that the controller operates as a closed-loop position controller while in the jog mode. The DMC-40x0
converts the velocity profile into a position trajectory and a new position target is generated every sample period.
This method of control results in precise speed regulation with phase lock accuracy.
Command Summary - Jogging
COMMAND DESCRIPTION
AC x,y,z,w Specifies acceleration rate
BG XYZW Begins motion
DC x,y,z,w Specifies deceleration rate
IP x,y,z,w Increments position instantly
IT x,y,z,w Time constant for independent motion smoothing
JG +/-x,y,z,w Specifies jog speed and direction
ST XYZW Stops motion
Parameters can be set with individual axes specifiers such as JGY=2000 (set jog speed for Y axis to 2000).
DMC-40x0 User Manual Chapter 6 Programming Motion 80
VELOCITY
(COUNTS/SEC)
20000
10000
5000
15000
20
40 60
80
TIME (ms)
100
X axis velocity profile
Y axis velocity profile
Z axis velocity profile
0

Table of Contents

Related product manuals