Command 248 (0xF8): Write the Factory Setting (cont.)
Command 253 (0xFD): Reset to Factory Setting
This command is to reset the setting to the factory setting.
Table 179: Command-Specific Response Codes
for Write the Factory Setting
Code Class Description
0 Success No Command-Specific Errors
1Undefined
2 Error Invalid Selection
3-4 Undefined
5 Error Too Few Data Bytes Received
6 Error Device-Specific Command Error
7 Error In Write Protect Mode
8-15 Undefined
16 Error Access Restricted
17-127 Undefined
Table 180: Request Data Bytes for Reset to Factory Setting
Byte Format Description
None
Table 181: Response Data Bytes for Reset to Factory Setting
Byte Format Description
None
Table 182: Command-Specific Response Codes for Reset to Factory Setting
Code Class Description
0 Success No Command-Specific Errors
1-4 Undefined
5 Error Too Few Data Bytes Received
6 Error Device-Specific Command Error
7Error In Write Protect Mode
8-15 Undefined
16 Error Access Restricted
17-127 Undefined