Chapter 5. Communication
84 AT600 User’s Manual
20A8 8360 User MultiK Reynolds KFactor5 RW (IEEE 32 bit)
20AA 8362 User MultiK Reynolds KFactor6 RW (IEEE 32 bit)
20C0 20C0 8384 User Correlation peak low limit RW (IEEE 32 bit)
20C2 8386 User Acceleration Limit RW (IEEE 32 bit)
20C4 8388 User
Velocity Low limit - Used for
Volumetric low limit
calculation RW (IEEE 32 bit)
20C6 User
Velocity High limit - Used for
Volumetric High limit
calculation RW (IEEE 32 bit)
20C8 8392 User
Amplitude discriminator min
limit RW (IEEE 32 bit)
20CA 8394 User
Amplitude discriminator
max limit RW (IEEE 32 bit)
20CC 8396 User Soundspeed Plus minus limit RW (IEEE 32 bit)
20CE 8398 User signal low limit RW (IEEE 32 bit)
20E0 20E0 8416 User Zero Cutoff RW (IEEE 32 bit)
20E2 8418 User DeltaT Offset RW (IEEE 32 bit)
2100 2100 8448 User Pipe Material RW INT32
2102 8450 User Lining Material RW INT32
2104 8452 User XDR Type RW INT32
2106 8454 User XDR frequency RW INT32
2108 8456 User XDR wedge type RW INT32
210A 8458 User Fluid Type RW INT32
210C 8460 User Lining existence RW INT32
210E 8462 User Traverse number RW INT32
2140 2140 8512 User Enable Reynolds Correction RW INT32
2142 8514 User Enable Active MultiK RW INT32
2144 8516 User MultiK Type RW INT32
2146 8518 User MultiK Pairs RW INT32
2180 2180 8576 User Peak% RW INT32
2182 8578 User Min Peak% RW INT32
2184 8580 User Max Peak% RW INT32
2186 8582 User Errors Allowed RW INT32
21C0 21C0 8640 User Enable Active TW RW INT32
21C2 8642 User Enable Tracking Windows RW INT32
21C4 8644 User Response Time RW INT32
Table 5: MODBUS Map (cont.)
Register
(in Hex)
Register (in
Decimal) Access Level Description RO/RW Format