Section 9 — Working with Routes
180
To configure a triaxial on-route recording on your instrument:
1. Open Ascent.
2. Right-click a location > Select Edit.
3. Choose one of the three available axes from the Triax Axis
dropdown list for each of the three locations.
NOTE: Each of the three locations must have a different/unique
Axis name and triaxial axis. Do NOT assign the same axis to more
than one location.
TIP: Use the Structure report in Ascent to review your database
setup and set the report to Machines, Points, Locations.
MORE: See your Ascent Software Reference Guide for more
information.
4. Saved a route and transfer it to your instrument.
5. Switch on your instrument.
6. Select the route you wish to record > Press .
7. Press Multi-Channel on Route on the route screen.
8. Check that Axis/Point Mode is set to Axes.
9. Press the button repeatedly to cycle through the two available
options.
10. Press Axis on CH2 — The Axis selection list will display.
NOTE: Triaxial recordings use channels 2, 3, and 4 on the
instrument via the 7-pin LEMO connector. BNC Channel 1 is NOT
available or used for this measurement type.
11. Select Triax Sensor from the selection list > Press .
12. Ensure channel 2 is assigned to the X axis.
13. Ensure channel 3 is assigned to the Y axis.
14. Ensure channel 4 is assigned to the Z axis.
15. Press .
NOTE: The channel configuration displayed beside Multi-
Channel on Route on the Route screen will read Triax Chan (1), 2, 3,
4. The (1) indicates that any locations which do NOT have a Triax
Axis set to X, Y, or Z will be recorded with channel 1. If your
instrument route screen indicates [CH1] beside a location, or asks
you to connect a sensor to channel 1, check the Triax Axis setting
at that location.
16. Press to take the triaxial measurement. The triaxial
measurements will be stored individually under their respective