Section 4 — Measurement Types and their Uses
56
To take a 6Pack measurement:
1. Press or Measure.
2. Press 6Pack.
3. Use the arrow keys on the left to select a parameter set or press
to create a new set.
4. Set the parameters as required.
5. Press Spectrum Waveform, HF Fmax (Dmax), or
Demod Band (Dmin).
6. Use keys , , and to select the measurement types
you wish to record.
7. Press to begin sampling.
NOTE: The six recording types that comprise a 6Pack
measurement are saved as a single recording for each channel,
not as individual High Frequency, Low Frequency, and
Demodulation.
Streamlined Parameter Settings
The following simplifications have been applied to 6Pack measurements:
• The sensor type must be Accelerometer.
• The High Frequency and Demodulation measurements are
measured in Acceleration units only.
• All spectra and waveforms have the same resolution (maximum
3200 lines, 40 kHz for single channel and 1600 lines, 20 kHz for
dual channel).
• The Demod Bandwidth upper limit is automatically set to equal
the HF Fmax.
• Averaging type, number, and overlap are the same for all
spectra.
• Fmin and Demodulation Fmin are the same.
• Fmax and Demod Fmax are the same.
NOTE: Several charts will display when you use the 6Pack feature,
especially when you measure with two channels.
MORE: See View Multiple Charts for more information on multi-
chart layout options.