Section  12  —  Balancing  Walkthrough 
240 
 
For  dual  plane  balancing,  perform  the  same  procedure 
for  Plane  B  —  Attach  a  trial  weight,  enter  its  position,  and 
specify  whether  weight  is  being  added  or  drilled  out.  If 
you  are  removing  trial  weights,  you  must  remove  the 
Plane  A  trial  weight  before  you  do  the  Plane  B  trial 
reading. 
 
Step 4 — Balance Rotor 
 
The  Balance  Weight  menu  displays  when  you  complete  the  Initial  and 
Trial  Readings.  Your  instrument  displays  the  weight  required  to  correct 
the  initial  imbalance  and  the  angular  position  at  which  it must  be 
attached. 
 
To  balance  the  rotor: 
1.  Stop  the  machine.   
 
IMPORTANT! If you are removing trial weights as you go, ensure 
you do this before attaching your correction weight. 
 
2.  Attach  or  remove  the  recommended  correction  weight  as indicated 
by  your  instrument.   
3.  Proceed  to  Trim  Balance.