Section 11 — Balancing Rotors
223
To specify your channel position:
1. Press Balance.
2. Press Setup.
3. Press # Sensors.
4. Select the number of sensors to use > Press .
5. Press CH1 Position > Enter the angle from the tachometer to
your sensor > Press .
6. For dual plane balancing, repeat the above step if you want your
instrument to recommend trial weight placement angles for both
planes.
Using channel position
Averages
Averaging the out of balance values can increase the accuracy of your
measurements. This enables your instrument to make more precise
recommendations for the size and placement of balance weights. A
higher number of averages produces more accurate measurements, but
lengthens the recording time accordingly.