Section 11 — Balancing Rotors
220
To perform a balancing operation:
1. Press Balance on the main menu.
2. Press New Job to clear your setting.
3. Press Setup to use your existing configuration.
4. Press Balance Planes > Use the arrow keys to select the
number of balance planes to use.
5. Press to proceed with your selection — The Balance Weight
Setup menu displays.
6. Press Plane A Weight Position.
7. Use the arrow keys to select the required option > Press .
8. Enter the required value > Press .
NOTE: If you select circumference arc or # fixed positions, the
Circumference or # Fixed Position submenus will open. Here you
need to specify the rotor circumference or the number of fixed
positions.
NOTE: You can set the circumference units used (inches or mm) in
the Balance Setup screen. To do this, press Weight Lin Dist >
Press Linear Distance.
9. Press Plane B Weight Position if you selected dual plane
balancing > Repeat the previous steps for Plane B.
10. Press repeatedly if necessary to return to the Balance Setup
menu and specify your sensor settings.
NOTE: If you selected dual plane balancing, pressing will
automatically take you to the Balance Sensor Setup menu.