Section 12 Balancing Walkthrough
238
11. Press to specify whether you are adding or removing (drilling
out) a weight.
12. Replace the safety covers.
13. Start the machine again.
14. Let the rotor settle to its normal operating speed.
15. Press to take a reading of the imbalance with the trial weight
added After a few seconds, the instrument displays the speed of
the rotor in RPM and Hz, the vibration level with the trial weight
added.